x
Send Your Inquiry Today
Quick Quote

Particle Counter Manufacturer In China

FLS is reliable airborne particle counting solutions for cleanrooms and critical production environments. With experienced engineers, strict quality control, and industry-focused expertise, we deliver reliable cleanroom pparticle counters for pharmaceutical, semiconductor, medical device, electronics, and other precision manufacturing applications.

。

  • particle counter
  • particle counter

Why trust Fulistech's particle counter?

  • Accurate Particle Measurement
  • Stable & Reliable Performance
  • Easy to Use & Efficient
  • Professional Technical Support

Your Trusted High-Quality particle counter Manufacturer

Fulistech is an experienced airborne pparticle counter manufacturer, specializing in particle detection and testing equipment for cleanroom and contamination control applications. Our engineering team focuses on detection accuracy, sampling performance, and data reliability, while strict quality control ensures consistent product performance.

Our cleanroom pparticle counters are designed for pharmaceutical, semiconductor, medical device, electronics, food, and optical applications. From product selection and technical consultation to after-sales support, Fulistech provides reliable particle monitoring solutions tailored to your testing needs.

。

Fulistech particle counter

particle counter
Fully Automatic Laser Particle counter

Fulistech particle counters deliver accurate detection, stable performance, and reliable data, providing efficient airborne particle monitoring solutions for pharmaceutical, semiconductor, medical device, and cleanroom applications.

Features of our airborne pparticle counters

Easy Operation
Easy Operation

An intuitive interface and simple workflow help you complete particle measurements quickly and efficiently.

Automatic Alarm
Automatic Alarm

The instrument automatically alerts you when measured particle levels exceed preset limits.

Audit Trail
Audit Trail

Automatically records key operations and test data for easy data traceability and quality management.

Automatic Cleanliness Classification
Automatic Cleanliness Classification

Automatically determines the cleanliness level based on measurement results, improving testing efficiency.

Designed for Consistent Particle Sampling

Fulistech airborne particle counters operate at a nominal sampling flow rate of 2.83 L/min, providing a defined sampling condition for cleanroom particle monitoring and contamination control. Built-in flow detection helps monitor the sampling flow, while the flow detection accuracy is subject to further technical confirmation. This allows you to select particle monitoring equipment based on clearly defined operating parameters.

Particle counter
Particle counter

Individual Functional Testing Before Delivery

Every Fulistech particle counter undergoes functional testing before shipment to check the operation of its key functions. This pre-delivery inspection helps identify functional issues before the instrument reaches your facility, giving you greater confidence during installation, commissioning, and routine use.

Built-In Data Storage for Monitoring Records

With built-in data storage, Fulistech particle counters can retain measurement records for subsequent review, depending on the model and its storage settings. This feature helps you organize particle monitoring results and supports routine cleanroom monitoring and quality control documentation

Particle counter
Particle counter

Practical Quality Assurance for Your Application

By combining a defined sampling flow rate, flow detection, pre-delivery functional testing, and data storage, Fulistech focuses on the practical requirements of particle monitoring. You can evaluate the instrument against your sampling needs, operating procedures, and documentation requirements before making a purchasing decision

FLS airborne particle counters ensure reliable testing solutions through rigorous quality management

company
company

Fulistech implements a structured quality management system covering incoming material inspection, production process control, product assembly, performance testing, and final inspection. Every testing machine and laboratory testing instrument undergoes functional testing before delivery to help identify potential issues and ensure that essential functions operate as intended.

For our airborne particle counters, the nominal sampling flow rate is 2.83 L/min, with built-in flow detection and data storage to support routine cleanroom particle monitoring and contamination control.

Additional performance verification, including sampling flow accuracy, particle counting efficiency, zero-count level, measurement repeatability, and continuous operation stability, can be specified according to the instrument model and verified test results.

By focusing on product-specific inspection procedures and measurable performance requirements, Fulistech provides reliable particle counting instruments, precision material testing equipment, and customized laboratory testing solutions to help you improve quality control efficiency, reduce measurement-related risks, and meet your application requirements.

Application of Fulistech particle counter

Pharmaceutical Manufacturing

Used for airborne particle monitoring in cleanrooms, sterile production areas, and pharmaceutical manufacturing environments to support environmental monitoring and quality control

Medical Device Manufacturing
Medical Device Manufacturing

Used to detect airborne particles in medical device production, packaging, and controlled clean areas, helping reduce the risk of particle contamination

Semiconductor & Electronics
Semiconductor & Electronics

Used for particle monitoring in semiconductor manufacturing, electronic component production, and cleanroom environments to help control airborne contamination.

Cleanrooms
Cleanrooms

Used for routine cleanroom particle monitoring, cleanliness classification, and environmental verification to ensure controlled areas consistently meet required cleanliness levels

Hospitals & Healthcare
Hospitals & Healthcare

Suitable for airborne particle monitoring in operating rooms, sterile areas, and other controlled healthcare environments to support environmental hygiene and contamination control

Food & Beverage
Food & Beverage

Used to monitor airborne particles in food processing, packaging, and controlled production areas, helping reduce environmental contamination risks

Optics & Precision Manufacturing
Optics & Precision Manufacturing

Used for particle detection in optical component and precision manufacturing environments, helping minimize the impact of airborne particles on product quality

Laboratories & R&D
Laboratories & R&D

Used for airborne particle measurement in laboratories, research centers, and other controlled environments, providing reliable data for environmental assessment and research

Parameters and 
Automatic alarm√
Level assessment√
Class 100-1 million√
AC/DC power supply√
Storage function√
Audio trace√
Access control√
Temperature and humidity detection※
Communication interface※
Sampling flow rate2.83 L/min
Display type5-inch color touchscreen
Battery capacityBuilt-in 4000 mAh battery
Average power consumption7.5 W
Dimensions220 × 230 × 150 mm (W × L × H)
Weight2.8 kg
Particle size channelsSix channels: 0.3, 0.5, 1.0, 3.0, 5.0, and 10 μm
Light sourceSemiconductor laser light source (lifespan > 30,000 hours)
Particle size distribution error0.5 μm, 5 μm: ≤±30%
Particle concentration indication error0.5 μm: ≤±30%
Detection rangeClass 100 to Class 1,000,000
UCL reportComplies with China GMP standards and FS-209E
Sampling cycle1 s – 9,999,999 s (user-defined)
Sampling delay1 s – 9,999,999 s (user-defined)
Number of sampling points2 – 50 points (user-defined)
Number of sampling cycles2 – 50 cycles (user-defined)
Sampling areaCustomizable alphanumeric combinations or user-defined settings
Sampling unitThree unit options: count, count/m³, count/ft³
Self-purification time≤10 min
Operating environmentTemperature: 10°C–35°C; Relative humidity: ≤75%; Atmospheric pressure: 86 kPa–106 kPa
Sampling conditionsSampled gas must not contain corrosive gases (e.g., acidic, alkaline, or high-temperature gases)
Data printingBuilt-in high-speed thermal printer
Accessories

Main unit, power adapter, printer paper, user manual, certificate of conformity

Parameters and Model

 

Automatic Alarm

√
Level Judgment

√

Class 100-1 Million

√
AC/DC Dual Power Supply

√

Storage Function

√

Audit Tracking

√

Access Control

√

Temperature and Humidity Detection

√

Communication Interface

RJ45、RS485

Sampling flow rate

28.3L/min

Display type

7-inch color touchscreen

Battery capacity

35,000 mAh

Average power consumption

90 W

Dimensions

300 × 300 × 300 mm

Weight

8.5 kg

Particle size channels

6 channels: 0.3, 0.5, 1.0, 3.0, 5.0, and 10 μm

Light source

Semiconductor laser light source (lifespan > 30,000 hours)

Particle size distribution error

0.5 μm, 5 μm: ≤±30%

Particle concentration indication error

0.5 μm: ≤±30%

Detection range

Class 100 to Class 1,000,000

UCL report

Complies with China GMP standards and FS-209E

Sampling cycle1 s – 999,999 s (user-defined)
Sampling delay1 s – 999,999 s (user-defined)
Number of sampling points2 – 50 points (user-defined)
Number of sampling cycles2 – 50 cycles (user-defined)

Sampling area

Customizable alphanumeric combinations or standalone settings

Sampling unit

Three unit options: count, count/m³, count/ft³

Self-purification time

≤10 min

Operating environment

Temperature: 10°C–35°C; Relative humidity: ≤75%; Atmospheric pressure: 86 kPa–106 kPa

Sampling conditions

Sampled gas must be free from corrosive gases (e.g., acidic, alkaline, or high-temperature gases)

Data printing

Built-in high-speed thermal printer

Accessories

Main unit, power adapter, printer paper, user manual, certificate of conformity

Parameters and 

 

 

 

 

Automatic alarm

√
Level assessment

√

Class 100-1 million

√

AC/DC power supply

√

Storage function

√

Audio trace

√

Access control

※

Temperature and humidity detection

※

Communication interface

※

Sampling flow rate

28.3L/min

Display type

7-inch color touchscreen

Battery capacity

35,000 mAh

Average power consumption

90 W

Dimensions

300 × 300 × 300 mm

Weight

8.5 kg
Particle size channels

6 channels: 0.3, 0.5, 1.0, 3.0, 5.0, and 10 μm

Light source

Semiconductor laser light source (lifespan > 30,000 hours)
Particle size distribution error

0.5 μm, 5 μm: ≤±30%

Particle concentration indication error

0.5 μm: ≤±30%
Detection rangeClass 100 to Class 1,000,000
UCL report

Compliant with China GMP standards and FS-209E

Sampling cycle

1 s – 999,999 s (user-defined)
Sampling delay1 s – 999,999 s (user-defined)
Number of sampling points

2 – 50 sampling points (user-defined)

Number of sampling cycles

2 – 50 sampling cycles (user-defined)

Sampling area

Customizable alphanumeric combinations or user-defined settings

Sampling unit

Three unit options: count, count/m³, count/ft³

Self-purification time

≤10 min

Operating environment

Temperature: 10°C–35°C; Relative humidity: ≤75%; Atmospheric pressure: 86 kPa–106 kPa

Sampling conditions

The sampled gas must not contain corrosive gases, such as acidic or alkaline gases, nor be at a high temperature.

Data printing

Built-in high-speed thermal printer

Accessories

Main unit, power adapter, printing paper, user manual, certificate of conformity

Parameters and

 
Automatic alarm

√

Level assessment

√

Class 100-1 million

√

AC/DC power supply

√

Storage function

√

Audio trace

√

Access control

√

Temperature and humidity detection

√

Communication interface

※

Sampling flow rate

2.83L/min

Display type

5-inch color touchscreen

Battery capacity

Built-in 4000mAh battery

Average power consumption

7.5W

Dimensions

220 x 230 x 150 mm (W x L x H)

Weight

2.8 kg
Particle size channels

6 channels: 0.3, 0.5, 1.0, 3.0, 5.0, 10 μm

Light source

Semiconductor laser light source (lifespan > 30,000 hours)
Particle size distribution error

0.5 μm, 5 μm: ≤±30%

Particle concentration indication error

0.5 μm: ≤±30%
Detection range

Class 100 to Class 1,000,000

UCL report

Complies with China GMP standards and FS-209E

Sampling cycle

1s – 9,999,999s (user-defined)

Sampling delay

1s – 9,999,999s (user-defined)

Number of sampling points

2 – 50 points (user-defined)
Number of sampling cycles

2 – 50 cycles (user-defined)

Sampling area

Customizable alphanumeric combinations or standalone settings

Sampling unit

Three unit options: count, count/m³, count/ft³

Self-purification time

≤10 min

Operating environment

Temperature: 10°C–35°C; Relative humidity: ≤75%; Atmospheric pressure: 86 kPa–106 kPa

Sampling conditions

Sample gas must not contain corrosive gases (acidic, alkaline, high-temperature, etc.)

Data printing

Built-in high-speed thermal printer
Accessories

Main unit, power adapter, printer paper, user manual, certificate of conformity

Parameters and

 

Automatic alarm

√

Level assessment

√

Class 100-1 million

√

AC/DC power supply

√

Storage function

※

Audio trace

※

Access control

※

Temperature and humidity detection

※

Communication interface

※

Sampling flow rate

2.83L/min

Display type

5-inch color touchscreen

Battery capacity

Built-in 4000mAh battery

Average power consumption

7.5W

Dimensions

220 x 230 x 150 mm (W x L x H)

Weight

2.8 kg

Particle size channels

6 channels: 0.3, 0.5, 1.0, 3.0, 5.0, 10 μm

Light source

Semiconductor laser light source (lifespan > 30,000 hours)

Particle size distribution error

0.5 μm, 5 μm: ≤±30%

Particle concentration indication error

0.5 μm: ≤±30%

Detection range

Class 100 to Class 1,000,000

UCL report

Complies with China GMP standards and FS-209E

Sampling cycle

1s – 9,999,999s (user-defined)

Sampling delay

1s – 9,999,999s (user-defined)

Number of sampling points

2 – 50 points (user-defined)

Number of sampling cycles

2 – 50 cycles (user-defined)

Sampling area

Customizable alphanumeric combinations or standalone settings

Sampling unit

Three unit options: count, count/m³, count/ft³

Self-purification time

≤10 min

Operating environment

Temperature: 10°C–35°C; Relative humidity: ≤75%; Atmospheric pressure: 86 kPa–106 kPa

Sampling conditions

Sample gas must not contain corrosive gases (acidic, alkaline, high-temperature, etc.)

Data printing

Built-in high-speed thermal printer

Accessories

Main unit, power adapter, printer paper, user manual, certificate of conformity

  • “We are very satisfied with the measurement accuracy and stability of the Fulistech pparticle counter. It provides reliable data for our cleanroom monitoring and quality control.”

  • “The pparticle counter is easy to use, and the touchscreen interface is very intuitive. Our operators can quickly learn how to perform daily particle measurements.”

  • “The automatic data storage and audit trail functions are very useful for our quality management. It makes historical data review and traceability much easier.”

  • “We use the pparticle counter for routine cleanroom monitoring, and its performance has been stable and consistent. It has become an important part of our environmental monitoring process.”

    user
  • “Fulistech provided professional technical support throughout the selection and installation process. Their team responded quickly and helped us choose the right particle monitoring solution for our application.”

What particle sizes can the pparticle counter detect?

Our laser pparticle counters support multiple particle size channels,It features a six-channel design, with channels at 0.3, 0.5, 1.0, 3.0, 5.0, and 10 μm., allowing you to monitor different airborne particle sizes for cleanroom environmental monitoring and quality control.

Can the pparticle counter automatically determine cleanroom cleanliness levels?

Yes. The cleanroom pparticle counter can automatically analyze measurement results and determine the applicable cleanliness level, helping you simplify routine cleanroom classification and particle monitoring.

How often does a pparticle counter need to be calibrated?

Perform calibration every 12 months (or every 6 months for demanding applications).

What technical support and after-sales service does Fulistech provide?

Fulistech provides professional technical support covering pparticle counter selection, installation guidance, operation training, troubleshooting, maintenance, and after-sales service, helping you maintain reliable long-term cleanroom particle monitoring performance.

Scroll to Top