x
Send Your Inquiry Today
Quick Quote
Oxygen Index Tester for Flame Performance Testing

Oxygen Index Tester For Flame Performance Testing

You can set the target oxygen concentration on the touch screen and let the instrument automatically balance the gas ratio, helping your lab reduce manual adjustment work and improve oxygen index test stability.

  • 0-100% oxygen concentration display range
  • Closed-loop oxygen concentration control
  • 0-20 L/min flow adjustment range
  • GB/T 2406.2-2009 design standard
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester
  • Oxygen Index Tester

Simpler Oxygen Index Testing

Oxygen concentration can be set directly on the touch screen, reducing repeated manual gas-flow adjustment.

Closed-loop control automatically brings oxygen concentration back to the target value, helping reduce test drift.

A stable-concentration beep prompt lets the operator know when the test condition is ready.

One-key calibration and one-key concentration ratio setting simplify routine operation.

Historical test data can be stored, queried, and cleared for easier laboratory record management.

Fault prompts help identify gas source issues, oxygen sensor problems, wrong oxygen/nitrogen connection, and sensor aging.

A Smarter Oxygen Index Tester For Plastics, Textiles, Building Materials, And Fire Doors

Oxygen index testing can become slow and unstable when operators must manually balance oxygen and nitrogen flow. If the oxygen concentration drifts during the test, your result may become difficult to trust. This automatic touch screen oxygen index tester helps you set the target concentration, automatically adjust the gas ratio, monitor faults, store data, and run tests with clearer prompts. For labs testing plastics, building materials, textiles, or fire doors, it gives you a more repeatable way to evaluate combustion behavior.

Touch Screen Oxygen Index Tester With Automatic Control

Automatic Touch Screen Oxygen Index Tester
Automatic Touch Screen Oxygen Index Tester

An intelligent oxygen index tester with automatic concentration control, touch screen operation, and closed-loop adjustment.

Closed-Loop LOI Testing System
Closed-Loop LOI Testing System

A laboratory combustion testing solution for plastics, building materials, textiles, fire doors, and other samples.

Advantage Of Oxygen Index Tester

Your testing work may involve plastics, textiles, building materials, fire doors, or formulation comparison. This tester helps you control oxygen concentration more automatically and reduce manual gas-ratio errors.

Plastic Flame Performance Testing
Plastic Flame Performance Testing

Test soft and hard plastics and evaluate how material combustion behavior changes under different oxygen concentrations.

Building Material Combustion Testing
Building Material Combustion Testing

Oxygen index data can support flame performance evaluation for various construction materials.

Textile and Soft Material Testing
Textile And Soft Material Testing

The optional non-self-supporting specimen clamp is suitable for textiles and other soft materials that cannot stand by themselves.

Fire Door Material Evaluation
Fire Door Material Evaluation

Relevant fire-door material samples can be tested under controlled oxygen and nitrogen conditions.

Stable Oxygen Concentration During Testing

Traditional oxygen index testers often require manual flow adjustment before the test, and once concentration drifts, the operator may not be able to correct it in time. That creates unstable results and wastes samples. With closed-loop control and a stepping proportional valve, this tester automatically corrects oxygen concentration drift during testing, helping your lab reduce operator dependence and improve result repeatability.

Stable Oxygen Concentration During Testing

Why Choose FOLISTECH?

Oxygen Index Tester
Oxygen Index Tester

When you choose FOLISTECH Oxygen Index Tester, you can confirm your sample type, combustion cylinder diameter, specimen clamp requirement, gas preparation, ignition workflow, and testing standard before ordering. Your samples may be rigid plastic, flexible textile, building material, or fire-door material. We help you match the configuration to the way you actually test, so your laboratory can start with fewer setup problems.

Application For Your Oxygen Index Testing Workflow

Plastic Material Oxygen Index Testing
Plastic Material Oxygen Index Testing

If you test soft or hard plastic materials, you need stable oxygen concentration control to compare flame performance between formulations or batches. The automatic adjustment workflow helps your team reduce manual gas-ratio errors.

Textile and Non-Self-Supporting Sample Testing
Textile And Non-Self-Supporting Sample Testing

If your sample cannot stand vertically by itself, you may need the optional non-self-supporting specimen clamp. This lets your lab fix two vertical edges of the specimen on the frame for softer materials such as textiles.

Building Material and Fire Door Evaluation
Building Material And Fire Door Evaluation

If your project involves building materials or fire-door materials, oxygen index data can help your team compare combustion behavior under controlled oxygen and nitrogen conditions.

Get an Instant Quote Now
Quick Quote
image banner

Oxygen Index Tester For More Repeatable Testing

  • Touch Screen Oxygen Setting
  • Automatic Gas Ratio Control
  • Fault and Sensor Prompts
  • Data Storage and History Query

Product Details Tab

StandardDescription
GB/T 2406.2-2009Design standard for oxygen index testing
ItemSpecification
Oxygen SensorImported oxygen sensor; digital oxygen concentration display without calculation; range 0-100%
Digital Resolution±0.1%
Measurement AccuracyClass 0.1
Oxygen Concentration AdjustmentTouch screen setting; program automatically adjusts oxygen concentration
Standard Oxygen Concentration InputSupported
Combustion Cylinder Diameter SettingCan be set; two common specifications optional
Flow Adjustment Range0-20 L/min (0-1200 L/h)
Quartz Glass CylinderChoose one of two specifications: inner diameter ≥75 mm or inner diameter ≥85 mm
Gas Flow Velocity in Combustion Cylinder40 mm±2 mm/s
Overall Dimensions650 mm x 400 mm x 830 mm
Pressure Gauge AccuracyClass 2.5
Pressure Gauge Resolution0.01 MPa
Test EnvironmentAmbient temperature: room temperature to 40℃; relative humidity: ≤70%
Input Pressure0.25-0.3 MPa
Working PressureNitrogen 0.15-0.20 MPa; oxygen 0.15-0.20 MPa
Applicable Specimen Clamp UseSoft and hard plastics, various building materials, textiles, fire doors, etc.
Ignition SystemPropane/butane ignition system
Ignition NozzleMetal tube with a nozzle at the tail end; inner diameter Φ2±1 mm; freely bendable and can enter the combustion cylinder to ignite the specimen
Flame Length16±4 mm
Flame Size Adjustment5 mm-60 mm, freely adjustable
Gas RequirementIndustrial nitrogen and oxygen, purity >99%; gas source and connectors prepared by user
Power RequirementAC220(+10%)V, 50Hz
Maximum Power150 W
Self-supporting Material Specimen ClampCan be fixed at the axial center of the combustion cylinder and vertically clamp the specimen
Non-self-supporting Material Specimen ClampCan fix two vertical edges of the specimen on the frame; optional, used for textiles and other soft non-self-supporting materials

Customer Feedback On Oxygen Index Tester

  • “With automatic oxygen concentration adjustment, our operator spends less time correcting gas flow and more time focusing on the sample and test result.”

    Mohammed Al Saud
    Farah Al-Khalid
    Laboratory QC Supervisor, Saudi Arabia
  • “Fault prompts, data storage, and historical query functions make oxygen index testing easier for our lab to manage and repeat.”

    Karim
    Daniel Mensah
    Materials Testing Engineer, Ghana
What is the Oxygen Index Tester used for?

The Oxygen Index Tester is used to test oxygen index and combustion behavior of soft plastics, hard plastics, building materials, textiles, fire doors, and other materials.

Which standard does the Oxygen Index Tester follow?

The Oxygen Index Tester is designed according to GB/T 2406.2-2009 for oxygen index testing.

How does the Oxygen Index Tester adjust oxygen concentration?

The Oxygen Index Tester allows users to set oxygen concentration on the touch screen, and the program automatically adjusts the gas ratio until the concentration reaches balance.

What is the oxygen concentration display range of the Oxygen Index Tester?

The oxygen concentration display range of the Oxygen Index Tester is 0–100%.

What is the flow adjustment range of the Oxygen Index Tester?

The flow adjustment range of the Oxygen Index Tester is 0–20 L/min, equivalent to 0–1200 L/h.

What gas source is required for the Oxygen Index Tester?

The Oxygen Index Tester requires industrial-grade oxygen and nitrogen with purity not less than 98%. The gas source and connectors are prepared by the user.

What is the power requirement of the Oxygen Index Tester?

The Oxygen Index Tester requires AC 220 V ±10%, 50 Hz power supply, with maximum power of 150 W.